Automated Clinical QA/QI
Review every chart. Focus people where judgment is needed.
EMS Intelligence screens incoming ePCRs against your QA indicators, links each potential finding to the chart evidence behind it, and gives qualified reviewers a prioritized queue to confirm, override or annotate.
Synthetic chart SYN-0117 · Respiratory distress · ALS · Unit M-12 (fictional)
- AutoNot metReviewerPending
G-04Repeat vital signs documented after treatment
Timeline rule
What the rule saw
Initial vitals 14:02. Albuterol 14:06. No subsequent vital set before transfer of care at 14:31.
AcceptOverrideAdd note - AutoMetReviewerMet
R-70Pre-therapy respiratory rate and SpO₂ documented
Timeline rule
- AutoMetReviewerMet
R-72Repeat bronchodilator dose interval per protocol
Timeline rule
- AutoHuman review requiredReviewerPending
M-68Dose appropriate for patient presentation
Clinical context
- AutoMetReviewerMet
G-09Transfer-of-care time and receiving facility recorded
Structured field
Automated results are proposals. A qualified reviewer accepts or overrides each one.
Human review, always
Software proposes. Qualified people decide.
Automated QA should take the repetitive checking off reviewers’ plates, not take clinical judgment away from them.
Clinical findings require qualified human review
Every automated result is a proposal. A qualified reviewer, QA coordinator or medical director confirms or overrides it before it becomes a finding. EMS Intelligence does not replace medical directors or clinical reviewers, and no automated QA system is 100% accurate.- Ambiguous clinical questions are routed to a person, never auto-scored
- Automated and human results are stored separately, so you can measure agreement
- Every override and its reason is kept in the audit history
Capabilities
What the QA/QI module does
Labels show what is available today and what is still being built.
How to read the labels on this page
- Available
- Built and in use in the platform today.
- Synthetic-data validated
- Built and tested against synthetic EMS charts; not yet validated on a live agency deployment.
- In development
- Actively being built. Not yet available to agencies.
- Planned
- On the roadmap. Scope and timing may change.
- Synthetic-data validated
Documentation review on every chart
Indicator rules check each imported chart for potential documentation gaps, such as missing reassessments, incomplete vital-sign sets or missing transfer-of-care details, instead of a small manual sample.
- Synthetic-data validated
Evidence-linked findings
Each potential finding shows what the rule saw in the chart, why the indicator matters and the agency policy it relates to, so reviewers can verify it quickly.
- Synthetic-data validated
Reviewer workflow
Reviewers accept, override or annotate every automated result. Automated proposals and human decisions are stored separately, and nothing is final until a person decides.
- Synthetic-data validated
Potential protocol concerns
Where a concern depends on clinical context, such as dose appropriateness or decision-making capacity in a refusal, the indicator is marked “Human review required” rather than scored automatically.
- Synthetic-data validated
Trend identification
Confirmed findings by indicator, unit, provider and month, with training recommendations and exportable reports for QA committees.
- Synthetic-data validated
Audit history
Who reviewed what, when, and why: decisions, overrides and reasons are recorded in an append-only audit trail.
- In development
Correction and re-evaluation workflow
Crews can mark a chart corrected today. Routing findings back to the crew, supervisor sign-off and automatic re-evaluation of the corrected chart are being completed.
- In development
Agency-specific QA criteria
Indicators are configured to the agency’s QA criteria and protocols during onboarding. Self-service rule authoring is not yet available.
- Planned
Additional clinical categories
Cardiac arrest, trauma, stroke, obstetrics, overdose and other categories are planned. Until they are built, those charts are routed to human review rather than scored.
How findings are produced
Deterministic rules first, private AI-assisted interpretation where it is validated
Deterministic rules
Findings come from transparent, versioned rules: a structured field is present or missing, an event happened within the protocol’s time window or it didn’t. The same chart always gives the same result, and the reviewer can see exactly which data the rule used.
Indicator sets built and tested on synthetic charts:
- General documentation completeness and timing
- Patient refusals, with capacity questions always sent to a human
- Medication administration documentation
- Respiratory distress and bronchodilator therapy, including repeat-dose timing
- Cardiac chest pain / STEMI documentation
Private AI-assisted interpretation
Some documentation questions can’t be answered from structured fields alone. For these, Mullen Analytics develops its own models that run privately inside the platform’s secure environment. No chart data is sent to an external AI service, and models are not trained on agency PHI.
- AI-assisted results are off by default and enabled only after validation for an agency’s data.
- AI never makes the final call and never scores a chart on its own.
- If the AI service is unavailable, results show as unavailable and reviewers continue manually. There is no silent fallback.
- Narrative interpretation beyond structured evidence is in development and is not part of current findings.
Validation status
Where the QA engine stands today
The indicator engine has been tested on designed synthetic charts with known answers to confirm that rules behave as specified. That shows the rules are built correctly. It is not a measure of clinical accuracy on real charts.
Before an agency relies on automated results, we measure agreement between automated proposals and its own reviewers’ decisions on its charts, and tune or disable indicators that don’t perform. We will share that evaluation with the agency’s QA leadership and medical director.
We don’t publish accuracy claims based on synthetic data.
See automated QA on synthetic charts.
We’ll walk through the reviewer workflow, evidence-linked findings and trend reporting, and discuss how your QA criteria would be configured.
Demonstrations use synthetic EMS data. Please don’t send patient information through this website.